SECTION 7. DELETIONS, ADDITIONS, MODIFICATIONS AND AMENDMENTS.
(C) Section 902.1 of the Uniform Fire Code, 1994 Edition, is hereby modified to include the following Standards for the construction of new streets within the Southern Platte Fire Protection District:
(1) The minimum roadway widths for streets shall be twenty-six (26) feet (back to back).
(2) The minimum roadway width for alleys shall be twenty (20) Feet.
(3) The turning radius of all cul - de - sacs and, dead-end streets shall be fifty (50) feet with a roadway having a minimum radius of forty (40) feet to the interior line.
(4) In the case of temporarily dead-end streets, which are stub streets designed to provide future connection with unsubdivided areas adjoining, the Board of Review may require a temporary easement for a turnaround with the same provisions provided in
Subparagraph (3) above, or a temporary roadway of at least twenty-six (26) feet in width of not excessive length to connect the temporary dead-end with an existing street.
(5) Streets shall be built so that grades shall not exceed fifteen (15%) percent.
(6) The provisions of this paragraph shall apply only to subdivisions within the Southern Platte Fire Protection District which have not been submitted to the proper zoning authority by April 14, 1997. This section is not intended to apply to single-family houses not included in any subdivision.
|